Part Number
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
14304 | HARRIS CORPORATION DBA HARRIS RF COM |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 55.0 SINGLE SECTION |
AAPN | SECTION QUANTITY | 1 |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.25 FREE AIR SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 100.000 KILOHMS SINGLE SECTION |
AEFK | MAXIMUM STARTING TORQUE | 6.00 INCH-OUNCES |
AEFM | MAXIMUM STOP TORQUE | 48.00 INCH-OUNCES |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 260.0 NOMINAL |
AXGY | MOUNTING METHOD | TERMINAL |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -30.0/+30.0 SINGLE SECTION |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.156 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 100.0 SINGLE SECTION |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAQL | BODY STYLE | CYLINDRICAL |
ABJT | TERMINAL LENGTH | 0.141 INCHES NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.172 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.196 INCHES NOMINAL |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 260.0 NOMINAL |
CBBL | FEATURES PROVIDED | HUMIDITY PROOF |
ABPM | BODY DIAMETER | 0.594 INCHES NOMINAL |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
AEFL | MAXIMUM RUNNING TORQUE | 6.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.344 INCHES NOMINAL |