Part Number
Part Number:
NSN:
NIIN:
Item Name:
OSCILLOGRAPH
Definition:
AN ITEM WHICH MAKES A PERMANENT VISUAL RECORD OF VALUES AND VARIATIONS IN ELECTRICAL VOLTAGE, AND OF QUANTITIES WHICH CAN BE CONVERTED INTO TERMS OF ELECTRICAL POTENTIAL. FOR ITEMS THAT ARE NOT SEPARABLE AND OPERABLE WHEN DETACHED FROM EQUIPMENT OF WHICH THEY ARE A PART (BUILT INTO OPERATIONAL END EQUIPMENT), SEE INDICATOR (2) (AS MODIFIED); MONITOR (AS MODIFIED); AND RECORDER (AS MODIFIED). SEE ALSO OSCILLOSCOPE.
CAGE Information
Code | Company |
---|---|
80058 | JOINT ELECTRONICS TYPE DESIGNATION S |
Federal Supply Class
Title
ELECTRICAL AND ELECTRONIC PROPER
Inclusions:
INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.
Exclusions:
EXCLUDES RADIAC EQUIPMENT
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BKCD | EVENT MARKER | PROVIDED |
BKCC | AMPLITUDE DEFLECTION FREQUENCY RANGE | 80 MM AT 0 TO 35 HZ; 40 MM AT 0 TO 60 HZ; 15 MM AT 0 TO 100 HZ; 4 MM AT 0 TO 200 HZ |
AMQY | INSTALLATION DESIGN | PORTABLE |
FEAT | SPECIAL FEATURES | 8.375 IN. BY 10.500 IN. BY 11.500 IN. O/A DIM. |
BKBY | RECORDING FREQUENCY RANGE IN HERTZ | +0.0/+200.0 |
AMSE | VOLTAGE RATING | 115.0 VOLTS NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
BKBZ | SENSITIVITY DEFLECTION PER VOLT IN MILLIMETERS | 0.50 |
ANBK | RECORDING METHOD | INK CHART PAPER |
BKCB | CHART SPEED | 10.0 MILLIMETERS PER SECOND AND 5.0 MILLIMETERS PER SECOND AND 20.0 MILLIMETERS PER SECOND AND 1.0 MILLIMETERS PER SECOND AND 0.1 MILLIMETERS PER SECOND AND 0.2 MILLIMETERS PER SECOND AND 0.05 MILLIMETERS PER SECOND AND 2.0 MILLIMETERS PER SECOND AND 0.5 MILLIMETERS PER SECOND AND 50.0 MILLIMETERS PER SECOND AND 100.0 MILLIMETERS PER SECOND AND 200.0 MILLIMETERS PER SECOND |
ACDC | CURRENT TYPE | AC |
BKBX | RECORDING CHANNEL QUANTITY | 2 |
FAAZ | PHASE | SINGLE |