Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
98330 | OECO, LLC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABMK | OVERALL WIDTH | 10.250 INCHES MINIMUM AND 10.370 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 6.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 7.500 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.651 INCHES MINIMUM SINGLE GROUP AND 0.660 INCHES MAXIMUM SINGLE GROUP |
ABKW | OVERALL HEIGHT | 7.750 INCHES NOMINAL |
ADAQ | BODY LENGTH | 9.880 INCHES MINIMUM AND 10.000 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ABHP | OVERALL LENGTH | 9.880 INCHES MINIMUM AND 10.000 INCHES MAXIMUM |