Definition:

AN ITEM CONSISTING OF ONE OR MORE DEFINITE LENGTHS OF STRAIGHT OR FORMED, FLEXIBLE OR RIGID, PREFABRICATED HOLLOW TUBING OF CONDUCTIVE MATERIAL. THE TUBING HAS A PREDETERMINED CROSS SECTION AND IS DESIGNED TO GUIDE OR CONDUCT HIGH FREQUENCY ELECTROMAGNETIC ENERGY THROUGH ITS INTERIOR. ONE OR MORE ENDS ARE TERMINATED. MAY INCLUDE COMMON MOUNTING OF A SWITCH, WAVE GUIDE, A DUMMY LOAD, ELECTRICAL AND OTHER COMPONENTS SUCH AS WAVEGUIDE SECTION, CABLE TERMINAL CHAMBER AND THE LIKE. EXCLUDES COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; AND TUNER, WAVEGUIDE.

CAGE Information

Code Company
06351 MICROWAVE ENGINEERING CORPORATION DB

Federal Supply Class

Title

ANTENNAS, WAVEGUIDES, AND RELATE

Inclusions:

INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.

Exclusions:

EXCLUDES TOWER STRUCTURES.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AAJD THREAD CLASS 2B FIRST FLANGE ALL CONNECTION FACILITIES
AHTX INSERTION LOSS IN DECIBELS 0.35
THSD THREAD SERIES DESIGNATOR UNC FIRST FLANGE ALL CONNECTION FACILITIES
AHSF FLANGE QUANTITY 2
CQGM MAXIMUM OPERATING PRESSURE 45.0 POUNDS PER SQUARE INCH GAGE
AAJF THREAD DIRECTION RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
AHTW VOLTAGE STANDING WAVE RATIO 1.28
MATT MATERIAL ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE
CSQT FLANGE CONNECTING FACILITY AND QUANTITY 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
CSFC WAVEGUIDE OUTSIDE HEIGHT 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM
AHRV TUBING WALL CONSTRUCTION STYLE SEAMLESS SINGLE TUBING SEGMENT
FLEX FLEXIBILITY RIGID SINGLE TUBING SEGMENT
CTCJ FLANGE STYLE COVER TYPE FIRST FLANGE
CQJX NOMINAL THREAD SIZE 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
AHSX FLANGE INSIDE WIDTH 1.118 INCHES MINIMUM FIRST FLANGE AND 1.126 INCHES MAXIMUM FIRST FLANGE
AAGR CROSS-SECTIONAL SHAPE STYLE INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
AHTD FLANGE DEPTH 0.610 INCHES MINIMUM FIRST FLANGE AND 0.640 INCHES MAXIMUM FIRST FLANGE
AHSY FLANGE INSIDE HEIGHT 0.493 INCHES MINIMUM FIRST FLANGE AND 0.501 INCHES MAXIMUM FIRST FLANGE
AHSZ FLANGE OUTSIDE WIDTH 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE
CRFH WAVEGUIDE INSIDE WIDTH 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM
CQHN WAVEGUIDE OUTSIDE WIDTH 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM
AHTA FLANGE OUTSIDE HEIGHT 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE
CRLB WAVEGUIDE INSIDE HEIGHT 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM

Similar Parts

R11-1639 , R111639 , 5985-01-401-5277 , 5985014015277 , 014015277