MOTOR , CONTROL
Definition:
A MOTOR WHICH IS DESIGNED TO BE OPERATED FROM TWO INDEPENDENT VOLTAGE SOURCES, IN SUCH A WAY THAT VARIATIONS IN ONE VOLTAGE SOURCE WILL DETERMINE THE DIRECTION AND SPEED OF THE MOTOR. IN THE ALTERNATING CURRENT TYPE THE VOLTAGES ARE USUALLY APPLIED TO A SPLIT-PHASE STATOR, WHEREAS IN THE DIRECT CURRENT TYPE, ONE VOLTAGE IS APPLIED TO THE STATOR AND THE OTHER TO THE ARMATURE. LOW INERTIA AND RAPID REVERSIBILITY ARE INHERENT CHARACTERISTICS OF THIS TYPE OF MOTOR. SEE ALSO SERVOMOTOR, AUTOMATIC PILOT.
CAGE Information
Code | Company |
---|---|
05088 | KEARFOTT CORPORATION DIV A SUBSIDIAR |
Federal Supply Class
Title
MOTORS, ELECTRICAL
Inclusions:
Exclusions:
EXCLUDES STARTING MOTORS FOR ENGINES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FREQ | FREQUENCY IN HERTZ | 300.0 INPUT OR 1800.0 INPUT |
ACDC | CURRENT TYPE | AC INPUT |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 115.0 LINE TO NEUTRAL SINGLE INPUT |
ANPZ | INCLOSURE FEATURE | TOTALLY INCLOSED |
CBBL | FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
CWFX | ROTOR SPEED RATING IN RPM | 5000.0 FIRST MULTIPLE FULL LOAD OR 10000.0 SECOND MULTIPLE FULL LOAD |
BFML | CONTROL FIELD WINDING TYPE | TWO WINDINGS, PARALLEL CONNECTED |
BKPQ | INCLOSURE SPECIFICATION | COMMERCIAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP COLLAR |
CWHZ | SHAFT END CHARACTERISTIC | A1 SINGLE STYLE SINGLE END |
AAJV | OVERALL WIDTH | 1.046 INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
ABWV | SHAFT DIAMETER | 0.1865 INCHES NOMINAL SINGLE END |
CWCS | LENGTH OF SHAFT FROM HOUSING | 0.500 INCHES SINGLE END |
CWDY | TEMP RATING | -54.0 OPERATING DEG CELSIUS AND 71.0 OPERATING DEG CELSIUS |
AXGY | MOUNTING METHOD | CLAMP RING |
FAAZ | PHASE | TWO INPUT |
AAJU | OVERALL LENGTH | 2.640 INCHES |
AAJT | OVERALL HEIGHT | 1.046 INCHES |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 50000.0 FEET |
BFMF | COOLING METHOD | NONVENTILATED |