Part Number
Part Number:
NSN:
NIIN:
Item Name:
MOTOR , CONTROL
Definition:
A MOTOR WHICH IS DESIGNED TO BE OPERATED FROM TWO INDEPENDENT VOLTAGE SOURCES, IN SUCH A WAY THAT VARIATIONS IN ONE VOLTAGE SOURCE WILL DETERMINE THE DIRECTION AND SPEED OF THE MOTOR. IN THE ALTERNATING CURRENT TYPE THE VOLTAGES ARE USUALLY APPLIED TO A SPLIT-PHASE STATOR, WHEREAS IN THE DIRECT CURRENT TYPE, ONE VOLTAGE IS APPLIED TO THE STATOR AND THE OTHER TO THE ARMATURE. LOW INERTIA AND RAPID REVERSIBILITY ARE INHERENT CHARACTERISTICS OF THIS TYPE OF MOTOR. SEE ALSO SERVOMOTOR, AUTOMATIC PILOT.
CAGE Information
Code | Company |
---|---|
88818 | KEARFOTT CORPORATION DBA KEARFOTT DI |
Federal Supply Class
Title
MOTORS, ELECTRICAL
Inclusions:
Exclusions:
EXCLUDES STARTING MOTORS FOR ENGINES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAJT | OVERALL HEIGHT | 0.938 INCHES |
BKPH | TORQUE RATING AND TYPE | 0.3 INCH-OUNCES STALLED |
ACDC | CURRENT TYPE | AC INPUT |
CWCS | LENGTH OF SHAFT FROM HOUSING | 0.190 INCHES SINGLE END |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 26.0 LINE TO NEUTRAL SINGLE INPUT |
ANPZ | INCLOSURE FEATURE | TOTALLY INCLOSED |
CBBL | FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
CWFX | ROTOR SPEED RATING IN RPM | 6500.0 SINGLE NO LOAD |
BKPB | CURRENT RATING METHOD | NO LOAD |
BFML | CONTROL FIELD WINDING TYPE | TWO WINDINGS, PARALLEL CONNECTED |
CWGL | CURRENT RATING IN AMPS | 0.166 SINGLE INPUT |
BKPQ | INCLOSURE SPECIFICATION | COMMERCIAL |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 80000.0 FEET |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP COLLAR |
FREQ | FREQUENCY IN HERTZ | 400.0 INPUT |
CWDY | TEMP RATING | 50.0 AMBIENT DEG CELSIUS AND -54.0 OPERATING DEG CELSIUS AND 165.0 OPERATING DEG CELSIUS |
AAJV | OVERALL WIDTH | 0.938 INCHES |
AAJU | OVERALL LENGTH | 1.170 INCHES |
BFMK | CONTROL FIELD IMPEDANCE RATING IN OHMS | 145.0 |
AXGY | MOUNTING METHOD | CLAMP RING |
TTQY | TERMINAL TYPE AND QUANTITY | 4 SOLDER LUG |
BKPS | CONTROL FIELD VOLTAGE TYPE AND RATING IN VOLTS | 26.0 AC |
FAAZ | PHASE | TWO INPUT |
BFMJ | CONTROL FIELD CURRENT RATING IN AMPS | 0.166 |
CWHZ | SHAFT END CHARACTERISTIC | A4 SINGLE STYLE SINGLE END |
ABWV | SHAFT DIAMETER | 0.0780 INCHES NOMINAL SINGLE END |
BFMF | COOLING METHOD | NONVENTILATED |