Part Number
Part Number:
NSN:
NIIN:
Item Name:
WAVEGUIDE ASSEMBLY
Definition:
AN ITEM CONSISTING OF ONE OR MORE DEFINITE LENGTHS OF STRAIGHT OR FORMED, FLEXIBLE OR RIGID, PREFABRICATED HOLLOW TUBING OF CONDUCTIVE MATERIAL. THE TUBING HAS A PREDETERMINED CROSS SECTION AND IS DESIGNED TO GUIDE OR CONDUCT HIGH FREQUENCY ELECTROMAGNETIC ENERGY THROUGH ITS INTERIOR. ONE OR MORE ENDS ARE TERMINATED. MAY INCLUDE COMMON MOUNTING OF A SWITCH, WAVE GUIDE, A DUMMY LOAD, ELECTRICAL AND OTHER COMPONENTS SUCH AS WAVEGUIDE SECTION, CABLE TERMINAL CHAMBER AND THE LIKE. EXCLUDES COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; AND TUNER, WAVEGUIDE.
CAGE Information
Code | Company |
---|---|
06351 | MICROWAVE ENGINEERING CORPORATION DB |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ACJL | BEND ANGLE IN DEG | 90.0 SINGLE BEND E-PLANE |
AHSX | FLANGE INSIDE WIDTH | 0.688 INCHES MINIMUM ALL FLANGES AND 0.694 INCHES MAXIMUM ALL FLANGES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CWBG | WAVEGUIDE OFFSET DISTANCE | 1.100 INCHES NOMINAL |
AAJD | THREAD CLASS | 2B FIRST FLANGE FIRST CONNECTION FACILITY |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.318 INCHES MINIMUM AND 0.324 INCHES MAXIMUM |
STYL | STYLE DESIGNATOR | BEND TYPE |
AHSF | FLANGE QUANTITY | 2 |
SFTT | SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE FIRST CONNECTION FACILITY |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.418 INCHES MINIMUM AND 0.424 INCHES MAXIMUM |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE FIRST CONNECTION FACILITY |
AHSE | TUBING MANUFACTURER PART NUMBER (NON-CORE) | M23351/4-037 SINGLE TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES FIRST FLANGE FIRST CONNECTION FACILITY |
CSPL | WAVEGUIDE LONGER OFFSET DISTANCE | 1.100 INCHES NOMINAL |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHTX | INSERTION LOSS IN DECIBELS | 0.30 |
CTCJ | FLANGE STYLE | CONTACT, DOUBLE RIDGE TYPE ALL FLANGES |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR DOUBLE INDENTED |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.688 INCHES MINIMUM AND 0.694 INCHES MAXIMUM |
AHTD | FLANGE DEPTH | 0.235 INCHES MINIMUM ALL FLANGES AND 0.265 INCHES MAXIMUM ALL FLANGES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
AHTA | FLANGE OUTSIDE HEIGHT | 1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES |
AHSY | FLANGE INSIDE HEIGHT | 0.318 INCHES MINIMUM ALL FLANGES AND 0.324 INCHES MAXIMUM ALL FLANGES |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.788 INCHES MINIMUM AND 0.794 INCHES MAXIMUM |
CMLP | THREAD QUANTITY PER INCH | 32 FIRST FLANGE FIRST CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.25 |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.148 INCHES MAXIMUM FIRST FLANGE SECOND CONNECTION FACILITY |
AHSZ | FLANGE OUTSIDE WIDTH | 1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 THREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.145 INCHES MINIMUM FIRST FLANGE SECOND CONNECTION FACILITY AND 0.145 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.148 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
AFJN | FRAGILITY FACTOR (NON-CORE) | MODERATELY RUGGED |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |