Part Number
Part Number:
NSN:
NIIN:
Item Name:
FILTER , BAND PASS
Definition:
AN ITEM DESIGNED TO PASS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO SUPPRESS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES A SINGLE INDUCTANCE, OR A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
01341 | MICROPHASE CORPORATION |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON THREE SURFACES |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 391.00 MEGAHERTZ 2ND BAND PASS AND 395.00 MEGAHERTZ 2ND BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 222.00 MEGAHERTZ 1ST BAND PASS AND 226.00 MEGAHERTZ 1ST BAND PASS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 7 TERMINAL |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 2.0 2ND BAND PASS |
ADAT | BODY WIDTH | 0.660 INCHES MINIMUM AND 0.700 INCHES MAXIMUM |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 1ST BAND PASS |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 254.00 MEGAHERTZ 1ST BAND PASS AND 30.00 MEGAHERTZ 1ST BAND PASS AND 191.00 MEGAHERTZ 1ST BAND PASS AND 555.00 MEGAHERTZ 1ST BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 14.0 1ST BAND PASS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
ABHP | OVERALL LENGTH | 5.340 INCHES MINIMUM AND 5.420 INCHES MAXIMUM |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 14.0 2ND BAND PASS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 391.0 HERCULES NO.5599.1 TWO PHASE TO TWO PHASE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 5 CONNECTOR |
ABKW | OVERALL HEIGHT | 1.950 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 12.5 MINIMUM 1ST BAND PASS AND 15.5 MAXIMUM 1ST BAND PASS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 222.0 HERCULES NO.5599.1 PULSES PER SECOND |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 12.5 MINIMUM 2ND BAND PASS AND 15.5 MAXIMUM 2ND BAND PASS |
ADAQ | BODY LENGTH | 4.980 INCHES MINIMUM AND 5.020 INCHES MAXIMUM |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 50.00 MEGAHERTZ 2ND BAND PASS AND 449.00 MEGAHERTZ 2ND BAND PASS AND 337.00 MEGAHERTZ 2ND BAND PASS AND 980.00 MEGAHERTZ 2ND BAND PASS |
ADAU | BODY HEIGHT | 1.230 INCHES MINIMUM AND 1.270 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | SWITCH CONTROL STANDARD TTL LOGIC INPUT |