Part Number
Part Number:
NSN:
NIIN:
Item Name:
RESISTOR , FIXED , WIRE WOUND , NONIND
Definition:
INC 37404 REINSTATED ON 010303~A RESISTOR WHOSE OHMIC VALUE CANNOT BE ADJUSTED OR VARIED. THE RESISTANCE ELEMENT CONSISTS OF HIGH RESISTANCE WIRE (OR RIBBON) EITHER WOUND ON AN INSULATED FORM OR CONSTRUCTED SO AS TO BE SELF-SUPPORTING. THE ITEMS MUST HAVE INHERENT CHARACTERISTICS OF INDUCING LITTLE OR NO SELF-INDUCTANCE. OPPOSITION TO CURRENT FLOW IS AN INHERENT PROPERTY OF THE RESISTANCE WIRE AND IS MANIFESTED BY THE HEAT DISSIPATION IN THE RESISTOR. EXCLUDES SUPPRESSOR, IGNITION INTERFERENCE. SEE ALSO RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-18546/2 GOVERNMENT SPECIFICATION |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0/+50.0 |
ABJT | TERMINAL LENGTH | 1.188 INCHES MINIMUM AND 1.312 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.125 INCHES MAXIMUM |
BYML | MOUNTING HOLE SIZE | 0.188 INCHES NOMINAL |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-18546 SPECIFICATION |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+255.0 |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL (S) |
AAQZ | INCLOSURE METHOD | ENCASED |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
ADAU | BODY HEIGHT | 2.188 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 4.5000 INCHES MAXIMUM |
AAPP | ELECTRICAL RESISTANCE | 1.100 OHMS |
AEFB | POWER DISSIPATION RATING IN WATTS | 75.000 FREE AIR |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000/+1.000 |
AARB | TERMINAL TYPE | WIRE LEAD |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |