Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , THERMAL
Definition:
A RELAY SWITCH WHICH IS ACTUATED BY THE EFFECT OF INTERNAL HEAT GENERATED BY THE CURRENT IN ITS ENERGIZING CIRCUIT. FOR ITEMS ACTUATED BY AMBIENT, RATHER THAN INTERNAL TEMPERATURE CHANGES, SEE SWITCH, THERMOSTATIC.
CAGE Information
Code | Company |
---|---|
93929 | SPX CORPORATION DBA RADIODETECTION |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CYCW | DELAY TIME IN SECONDS | 22.0 ADJUSTABLE OPERATE MINIMUM AND 33.0 ADJUSTABLE OPERATE MAXIMUM |
CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
ABKW | OVERALL HEIGHT | 1.375 INCHES NOMINAL |
APFR | CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY CLOSED |
CYCV | HEATER POWER RATING IN WATTS | 4.0 |
CYCU | HEATER VOLTAGE RATING IN VOLTS | 28.0 |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
FEAT | SPECIAL FEATURES | TWO 0.130 IN. DIA MTG HOLES SPACED 1.125 IN. C TO C; 2 SEC RELEASE TIME |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN |
ABMK | OVERALL WIDTH | 1.000 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 2.375 INCHES NOMINAL |
CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS | 3.0 AC OR 1.0 DC |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |