Part Number
Part Number:
NSN:
NIIN:
Item Name:
GENERATOR SET , DIESEL ENGINE
Definition:
A GENERATOR SET USING A DIESEL ENGINE AS THE PRIME MOVER. EXCLUDES GENERATOR SET, DIESEL ENGINE, TRAILER MOUNTED.
CAGE Information
Code | Company |
---|---|
50309 | JOHN REINER & CO. INC. |
Federal Supply Class
Title
GENERATORS AND GENERATOR SETS, E
Inclusions:
INCLUDES ENGINE, TURBINE, WIND, AND HAND DRIVEN GENERATOR SETS AND AUXILIARY AIRCRAFT GENERATORS.
Exclusions:
EXCLUDES MOTOR-CONVERTERS; MOTOR-GENERATOR SETS; ENGINE GENERATORS; ENGINE ACCESSORY GENERATORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AYQZ | PRIME MOVER STARTING METHOD | EXCITER |
ACYR | DC VOLTAGE RATING | 12.0 VOLTS NOMINAL |
AYHE | EXCITOR TYPE | SELF-EXCITED |
ACUT | DIRECT CURRENT RATING IN AMPS | 8.3 |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
AQGA | MANUFACTURER NAME | NORWALL POWER SYSTEMS |
SUPP | SUPPLEMENTARY FEATURES | VOLTAGE REGULATOR: CONDENSOR TYPE; FREQUENCY: 60 HZ; FUEL TANK CAPACITY:4.23 GALLONS (16.0L); 8.0 HOURS CONTINUOUS HOURS; POWER FACTOR: 1.0; ENGINE MODEL: DY41D |
AYHA | DC WATTAGE RATING | 100.0 WATTS |
AGAV | END ITEM IDENTIFICATION | 5000E PORTABLE GENERATOR SET |
AMSB | IDENTIFYING NUMBER | RGD5000E MODEL NO. |
AYGY | AC WATTAGE RATING | 4500.0 WATTS |
AYHB | LINE TO LINE VOLTAGE IN VOLTS | 120.0 AND 240.0 |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED |
ACDC | CURRENT TYPE | AC AND DC |
FAAZ | PHASE | SINGLE |
FEAT | SPECIAL FEATURES | MAY ALSO BE POWERED BY JP-5 JET FUEL OR DIESEL LIGHT OIL |