Part Number
Definition:
A TEST SET WHOSE PRIMARY FUNCTION IS TO MEASURE THE OPTICAL POWER LEVEL AVAILABLE FROM A LIGHT EMITTING SOURCE, SUCH AS LIGHT EMITTING DIODE, LASER DIODE. THIS TEST SET WILL ALSO MEASURE THE OPTICAL POWER LEVELS AT THE RECEIVER END OF AN OPTICAL FIBER.
CAGE Information
Code | Company |
---|---|
0XGW3 | LASER PROBE, INC. |
Federal Supply Class
Title
OPTICAL INSTRUMENTS, TEST EQUIPM
Inclusions:
INCLUDES BINOCULARS; MAGNIFIERS; MICROSCOPES; PERISCOPES; TELESCOPES; OPTICAL ELEMENTS; SUCH AS LENS, PRISMS, WINDOWS; OPTICAL BENCHES AND ASSOCIATED DEVICES; ENDOSCOPES, FIBER OPTICS (NON-MEDICAL).
Exclusions:
EXCLUDES FIRE CONTROL INSTRUMENTS, OPTICAL; SURVEYING INSTRUMENTS, OPTICAL; PHOTOGRAMMETRIC INSTRUMENTS; OCTANTS; AND SEXTANTS; OPTICAL INSTRUMENTS INTEGRATED WITH FIRE CONTROL EQUIPMENT; OPTHALMOLOGICAL INSTRUMENTS; ELECTRONIC FIBER OPTIC TEST EQUIPMENT; MEDICAL ENDOSCOPES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FTLD | FUNCTIONAL DESCRIPTION | MEASURES TRUE ENERGY/PULSE FROM A SINGLE-SHOT TO 40HZ, PICCO JOULES TO JOULES, UV TO FAR-IR. SETS OF 10 TO 100 PULSES CAN BE STATISTICALLY AND ANALYZED, AND THE DATA CAN BE TRANSFERRED TO A COMPUTER VIA AN IEEE48 INTERFACE BUS. ACCEPTS 2 PROBES AND SIMUTANEOUSLY DISPLAYS THE ENERGY INCIDENT ON CHANNELS A AND B, AS WELL THE RATIO OF CHANNEL B/CHANNEL A. MAUFACTURES NAME ENERGY METER/RATIOMETER |
FEAT | SPECIAL FEATURES | 2HANNEL RATIOING CAPABILITY; HIGH RESOLUTION DISPLAY, 1 PART IN 3000; MEASUREMENT SPEEDS UP TO 40 PULSES/SECOND; PORM 5% ACCURACY; STATISTICAL ANALYSIS OF REPETITIVE PULSES: 10 OR 100 PULSE AVERAGE, MIN & MAX ENERGY AND STANDARD DEVIATION; 64 CHARACTER ALPHANUMERIC LCD DISPAY; DIGITAL COMPEMSATION FOR: WINDOW.FILTER/BEAM SPLITTER ATTENUATOR LOSS OR NORMALIZING DETECTOR RESPONSE (RANGE 0.1 TO 1.0); INTERCHANGEANLE WINDOW/FILTERS/ATTENUATORS; AUXILIARY WINDOW/FILTERS/ATTENUATORS; AUCILIARY ANALOG OUTPUTS |
RDAL | REFERENCE DATA AND LITERATURE | MANUFACTURERS COMMERCIAL LITERATURE |
ACYN | AC VOLTAGE RATING | 115.0 VOLTS NOMINAL AND 240.0 VOLTS NOMINAL |
ABGL | WIDTH | 10.000 INCHES NOMINAL |
AQXZ | OPERATING TEST CAPABILITY | 14 DECADES 10 TO THE -12TH (PICAJOULES) TO 100 JOULES DEPENDING ON WHICH OF 8 PROBES ARE USED |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
AQXY | TEST TYPE FOR WHICH DESIGNED | OPTICAL ENERGY MEASUREMENTS IN JOULES |
HGTH | HEIGHT | 4.000 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
FAAZ | PHASE | SINGLE |
ABRY | LENGTH | 12.000 INCHES NOMINAL |