Part Number
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 0.402 INCHES MINIMUM |
ABKW | OVERALL HEIGHT | 0.402 INCHES MINIMUM |
AAPN | SECTION QUANTITY | 1 |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.25 FREE AIR SINGLE SECTION |
ABWV | SHAFT DIAMETER | 0.075 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -250.0/+250.0 SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
ABXF | SHAFT LENGTH | 0.050 INCHES MAXIMUM |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-22097 SPECIFICATION |
ABMK | OVERALL WIDTH | 0.165 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 0.320 INCHES MAXIMUM |
AAQL | BODY STYLE | RECTANGULAR |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAU | BODY HEIGHT | 0.250 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.172 INCHES MINIMUM |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.165 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
ADAQ | BODY LENGTH | 0.250 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 20.0 KILOHMS SINGLE SECTION |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-22097/5 GOVERNMENT SPECIFICATION |
APXH | TERMINAL LOCATION | RIGHT ADJACENT SIDE TWO ROWS |