Part Number
Definition:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. THE ITEM MAY HAVE SPECIAL INPUT, OUTPUT, CONTROL OR OTHER FACILITIES FOR APPLICATIONS IN SPECIALIZED ENVIRONMENTS SUCH AS MEDICAL, DENTAL OR OTHER OPERATIONS. EXCLUDES BATTERY CHARGERS AND ROTATING MACHINERY TYPES OF ITEMS, SUCH AS MOTOR GENERATORS AND DYNAMOTORS.
CAGE Information
Code | Company |
---|---|
10610 | SPELLMAN HIGH VOLTAGE ELECTRIC CORPO |
Federal Supply Class
Title
CONVERTERS, ELECTRICAL, NONROTAT
Inclusions:
INCLUDES COMPLETE BATTERY CHARGING EQUIPMENT, NONROTATING; POWER SUPPLIES, MULTIAPPLICATION.
Exclusions:
EXCLUDES RECTIFYING TUBES; (FSC 5960); RECTIFYING CRYSTALS (FSC 5961); ROTATING EQUIPMENT (FSC 6125); TRANSFORMERS (FSC 5950); AND SEMICONDUCTOR DEVICES AND ASSOCIATED HARDWARE (FSC 5961).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
APNX | INPUT VOLTAGE RATING | 28.0 DC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 5100.0 AC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 20000.0 AC VOLTS NOMINAL 1ST POWER OUTPUT |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
CWGH | OUTPUT CURRENT RATING | 0.0 AC MICROAMPERES MINIMUM 2ND POWER OUTPUT AND 200.0 AC MICROAMPERES MAXIMUM 2ND POWER OUTPUT |
ABKW | OVERALL HEIGHT | 2.650 INCHES NOMINAL |
CWHF | OUTPUT CONNECTION QUANTITY | 12 SINGLE POWER OUTPUT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
CWHM | INPUT CURRENT RATING | 0.0 DC MILLIAMPERES MINIMUM SINGLE OPERATING POWER RQMT AND 700.0 DC MILLIAMPERES MAXIMUM SINGLE OPERATING POWER RQMT |
ABHP | OVERALL LENGTH | 17.000 INCHES NOMINAL |
CWGN | OUTPUT PHASE | SINGLE SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | WIRE LEAD SINGLE POWER OUTPUT |
ABMK | OVERALL WIDTH | 7.000 INCHES NOMINAL |
AYNH | OPERATING AMBIENT TEMP RANGE | -0.1/+50.0 DEG CELSIUS |
FEAT | SPECIAL FEATURES | ALTITUDE OPERATING RANGE:5000 FT/NON-OPERATING - 40000 FT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC MICROAMPERES MINIMUM 1ST POWER OUTPUT AND 150.0 AC MICROAMPERES MAXIMUM 1ST POWER OUTPUT |