Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
00779 | TYCO ELECTRONICS CORPORATION |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
ADAV | OVERALL DIAMETER | 2.060 INCHES NOMINAL |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 12.0 MILLIAMPERES DC SINGLE WINDING |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 5C |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
APNA | WINDING DC RESISTANCE RATING | 14.0 KILOHMS NOMINAL SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 50.0 DC |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | INERT GAS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES DC RESISTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 17 PIN ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 2.560 INCHES NOMINAL |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE SINGLE MOUNTING FACILITY |