Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
00779 TYCO ELECTRONICS CORPORATION

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
AKDX WINDING QUANTITY 1
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 1
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 50.0 AC
APNA WINDING DC RESISTANCE RATING 300.0 OHMS NOMINAL SINGLE WINDING
ABKW OVERALL HEIGHT 1.430 INCHES NOMINAL
ADZC ENVIRONMENTAL PROTECTION HERMETIC
APNP DUTY TYPE CONTINUOUS
ABMK OVERALL WIDTH 1.620 INCHES NOMINAL
AGAV END ITEM IDENTIFICATION TYPE NO. AN/FPS-6A
ABHP OVERALL LENGTH 2.810 INCHES NOMINAL
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 3.0 AMPERES AC INDUCTIVE LOAD
AYSC PILE-UP MAIN CONTACT FORM ARRANGEMENT 1C AND 1C
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 900.0 MILLIAMPERES DC SINGLE WINDING
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING

Similar Parts

RP4081G1 , RP4081G1 , 5945-00-258-3386 , 5945002583386 , 002583386