Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
02116 | COOPER WHEELOCK INC. |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN ALL FUNCTIONS |
AKDX | WINDING QUANTITY | 1 |
AJSS | FREQUENCY IN HERTZ | 45.0 MINIMUM AND 65.0 MAXIMUM |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.960 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.340 INCHES NOMINAL |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |
AAJD | THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 0.15 AMPERES AC SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
APNP | DUTY TYPE | CONTINUOUS |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2A |
APNA | WINDING DC RESISTANCE RATING | 831.0 OHMS NOMINAL SINGLE WINDING |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 1.960 INCHES NOMINAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC RESISTIVE LOAD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED HOLE SINGLE MOUNTING FACILITY |