Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC INDUCTIVE LOAD |
AKDX | WINDING QUANTITY | 1 |
ADAV | OVERALL DIAMETER | 1.200 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 1.940 INCHES NOMINAL |
APCN | COIL QUANTITY | 1 |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 26.5 DC |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.1500 SECONDS NOMINAL FIXED OPERATE TIME |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CRXH | TIME DELAY | 0.010 SECONDS NOMINAL FIXED RELEASE TIME |
ZZZT | NONDEFINITIVE SPEC/STD DATA | RY4LC1A3L01 TYPE |
APNP | DUTY TYPE | CONTINUOUS |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.152 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |