Part Number
Part Number:
NSN:
NIIN:
Item Name:
RESISTOR , FIXED , FILM
Definition:
A RESISTOR WHOSE OHMIC VALUE CANNOT BE ADJUSTED OR VARIED. THE RESISTANCE ELEMENT CONSISTS OF EITHER A THIN LAYER OF CONDUCTIVE MATERIAL, CONTAINING EITHER BINDERS OR INSULATING MATERIALS, DEPOSITED ON AN INSULATED FORM; OR AN ALLOY OF METAL AND CERAMIC MATERIALS, USUALLY FUSED TO AN INSULATED FORM. OPPOSITION TO THE FLOW OF CURRENT IS AN INHERENT PROPERTY OF THE MATERIALS USED AND IS MANIFEST BY THE HEAT DISSIPATION IN THE RESISTOR. SEE ALSO ATTENUATOR, FIXED AND RESISTOR, FIXED, COMPOSITION. EXCLUDES CARBON COMPOSITION TYPE RESISTORS.
CAGE Information
Code | Company |
---|---|
18612 | VISHAY INTERTECHNOLOGY INC. |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.500/+0.500 |
CRTL | CRITICALITY CODE JUSTIFICATION | ZZZY |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 175.0 |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP |
ADAQ | BODY LENGTH | 0.302 INCHES NOMINAL |
PKWT | UNPACKAGED UNIT WEIGHT | 0.6 GRAMS |
FEAT | SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO3481 |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
STYL | STYLE DESIGNATOR | TERMINALS ONE EDGE |
AAPP | ELECTRICAL RESISTANCE | 2.320 KILOHMS |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
ADAT | BODY WIDTH | 0.326 INCHES NOMINAL |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | +0.0/+60.0 |
ABJT | TERMINAL LENGTH | 1.000 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.300 FREE AIR |
AARB | TERMINAL TYPE | WIRE LEAD |
ADAU | BODY HEIGHT | 0.105 INCHES NOMINAL |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -1.0/+1.0 |