Part Number
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
54418 | MILTOPE CORPORATION DBA VT MILTOPE |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.75 7TH SECONDARY QUALITY |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.75 7TH SECONDARY QUALITY |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
ABJT | TERMINAL LENGTH | 0.185 INCHES MINIMUM AND 0.255 INCHES MAXIMUM |
AAPN | SECTION QUANTITY | 1 |
ADAQ | BODY LENGTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 500.0 OHMS C AND BETTER FLOORING |
ADAT | BODY WIDTH | 0.280 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
ABWV | SHAFT DIAMETER | 0.090 INCHES MINIMUM AND 0.110 INCHES MAXIMUM |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 5400.0 NOMINAL |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABMK | OVERALL WIDTH | 0.270 INCHES MINIMUM AND 0.290 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.345 INCHES MINIMUM AND 0.375 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 0.045 INCHES MINIMUM AND 0.075 INCHES MAXIMUM |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 105.0 SINGLE SECTION |
ABKW | OVERALL HEIGHT | 0.520 INCHES MINIMUM AND 0.600 INCHES MAXIMUM |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CLUTCH |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.490 INCHES MINIMUM AND 0.510 INCHES MAXIMUM |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.190 NOMINAL MILS AND 0.210 NOMINAL CENTIMETERS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 25.0 SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 5400.0 NOMINAL |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
ABHP | OVERALL LENGTH | 0.780 INCHES MINIMUM AND 0.840 INCHES MAXIMUM |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0/+100.0 SINGLE SECTION |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.200 INCHES NOMINAL |