Part Number
Definition:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
58474 | SUPERIOR ELECTRIC HOLDING GROUP LLC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, HALF SHELL |
ADAU | BODY HEIGHT | 1.188 INCHES NOMINAL |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
AFFL | MOUNTING BOLT CIRCLE DIAMETER | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAQ | BODY LENGTH | 5.312 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRBZ | WINDING OPERATING CURRENT | 7.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
AARD | DUMMY TERMINAL QUANTITY (NON-CORE) | 1 |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ABTD | MOUNTING SLOT WIDTH | 0.276 INCHES NOMINAL SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 3 SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 3 THREADED STUD |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAT | BODY WIDTH | 5.094 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 115.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY OUTPUT |