Part Number
Part Number:
NSN:
NIIN:
Item Name:
THERMOSTAT , FLOW CONTROL
Definition:
AN AUTOMATIC REGULATING DEVICE WHICH CONTROLS THE FLOW OF FLUIDS OR GASES BY ACTUATING A VALVE OR SHUTTER FOR HEATING OR COOLING PURPOSES. MAY BE ADJUSTABLE, OR SET TO OPERATE AT A DEFINITE PRESSURE. EXCLUDES CONTROL, HUMIDITY; CONTROL, TEMPERATURE INDICATING; AND SWITCH, THERMOSTATIC.
CAGE Information
Code | Company |
---|---|
15434 | CUMMINS INC. |
Federal Supply Class
Title
PRESSURE, TEMPERATURE, AND HUMID
Inclusions:
INCLUDES THERMOMETERS, INCLUDING ENGINE THERMOMETERS; PRESSURE GAGES; THERMOCOUPLE LEADS; RESISTANCE BULBS.
Exclusions:
EXCLUDES CLINICAL THEROMETERS; (FSC 6515); THERMOSTATIC AND DIFFERENTIAL PRESSURE SWITCHES (FSC 5930); AND METEOROLOGICAL INSTRUMENTS (FSC 6660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AWTM | OPENING TEMP RATING | 145.0 DEG FAHRENHEIT MINIMUM AND 150.0 DEG FAHRENHEIT MAXIMUM |
ADJH | MOUNTING METHOD | FLANGE |
ABKW | OVERALL HEIGHT | 4.281 INCHES NOMINAL |
AMSD | VALVE TRAVEL DISTANCE | 0.469 INCHES NOMINAL |
AWTN | OPERATING TEMP RATING | 165.0 DEG FAHRENHEIT MINIMUM AND 170.0 DEG FAHRENHEIT MAXIMUM |
AGWM | LARGEST OUTSIDE DIAMETER | 2.462 INCHES MINIMUM AND 2.465 INCHES MAXIMUM |
ADQU | FLOW CONTROL DEVICE | BY-PASS |
AWPA | THERMOSTAT TYPE | BELLOWS |
AWTP | SPRING OPERATED PRESSURE RELIEF | NOT PROVIDED |
ALCD | USAGE DESIGN | MAINTAIN ENGINE COOLANT TEMP |