Part Number
Part Number:
NSN:
NIIN:
Item Name:
REACTOR-TRANSFORMER
Definition:
A COMPONENT CONSISTING OF TWO OR MORE ELECTRICALLY DISTINCT ITEMS. ONE OR MORE ITEMS ARE MADE OF ONE OR MORE COILS WHICH FUNCTION AS A REACTOR; AT LEAST ONE OTHER ITEM IS MADE OF A TAPPED COIL OR TWO OR MORE COILS WHICH FUNCTION AS A TRANSFORMER. THE ITEMS MAY HAVE A COMMON CORE, BUT ARE NOT MAGNETICALLY COUPLED.
CAGE Information
Code | Company |
---|---|
80023 | HIREL SYSTEMS LLC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE WINDING |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABMK | OVERALL WIDTH | 2.750 INCHES NOMINAL |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 0.013 SINGLE COMPONENT SINGLE WINDING |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM ALL COMPONENTS AND 430.0 HERTZ MAXIMUM ALL COMPONENTS |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE PRIMARY |
ABKW | OVERALL HEIGHT | 4.125 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 24 SCREW AND 9 TAB, SOLDER LUG |
CWJS | WINDING OPERATING VOLTAGE | 97.70 AC POUNDS PER HOUR DRY 2ND COMPONENT SINGLE PRIMARY AND 132.30 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND COMPONENT SINGLE PRIMARY |
ACYV | INDUCTANCE RATING | 180.00 MICROHENRIES NOMINAL 1ST COMPONENT SINGLE WINDING |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 20.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT SINGLE WINDING |
ABHP | OVERALL LENGTH | 4.750 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 425.00 AC POUNDS PER HOUR WET 2ND COMPONENT SINGLE SECONDARY |