Part Number
Definition:
AN ITEM CONSISTING OF A PARTIAL TURN AS ONE OR MORE TURNS OF WIRE OR OTHER CONDUCTIVE MATERIAL WHICH CONSTITUTES ONE CONTINUOUS UNTAPPED WINDING. IT MAY BE WOUND OR FORMED IN OTHER THAN A CIRCULAR MANNER AND MAY BE SELF-SUPPORTING, REQUIRING NO COIL FORM. IT IS SPECIFICALLY DESIGNED TO FURNISH INDUCTIVE REACTANCE IN A CIRCUIT CARRYING RADIO FREQUENCY CURRENT RANGING FROM 20 KILOHERTZ (KILOCYCLES) AND ABOVE. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). THE COIL HAS ONLY TWO ELECTRICAL TERMINALS. FOR ITEMS HAVING TAPPED WINDING OR MORE THAN ONE WINDING - SEE TRANSFORMER, RADIO FREQUENCY. FOR COILS WOUND ON RESISTORS, WHICH ARE DESIGNED TO BE INSERTED IN THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC.
CAGE Information
Code | Company |
---|---|
97953 | GE AVIATIONS SYSTEMS LLC DBA GE AVIA |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
ADAT | BODY WIDTH | 0.812 INCHES NOMINAL |
ADAU | BODY HEIGHT | 5.062 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.062 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TURRET |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 1B SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 1.260 SINGLE COMPONENT SINGLE WINDING |
ACYV | INDUCTANCE RATING | 50.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
AARD | DUMMY TERMINAL QUANTITY (NON-CORE) | 2 |
CMLP | THREAD QUANTITY PER INCH | 40 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |