BOILER , STEAM , HIGH PRESSURE
Definition:
A CLOSED METAL VESSEL CONSISTING OF A DRUM(S) OR SHELL AND NECESSARY TUBES, FITTINGS AND DIRECT CONNECTED END ITEMS. IT IS DESIGNED TO CONVERT WATER INTO STEAM BY APPLICATION OF HEAT. EXCLUDES LOW PRESSURE BOILERS UNDER 15 POUNDS (6.804 KG) PER SQUARE INCH (645.2 SQ MM) GAGE STEAM PRESSURE AND EVAPORATORS.
CAGE Information
Code | Company |
---|---|
80064 | NAVAL SHIP SYSTEMS COMMAND |
Federal Supply Class
Title
INDUSTRIAL BOILERS
Inclusions:
INCLUDES STEAM BOILERS, OVER 15 POUNDS WSP. MARINE BOILERS; BOILER DRUMS; WATER HEATERS, LOW PRESSURE (OVER 100 GALLON RECOVERY CAPACITY).
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BJDW | MAXIMUM OPERATING PRESSURE | 125.0 POUNDS PER SQUARE INCH GAGE |
BJDW | MAXIMUM OPERATING PRESSURE | 125.0 POUNDS PER SQUARE INCH GAGE |
ANCY | HORSEPOWER RATING | NOT RATED |
BLHL | STEAM CAPACITY | 2500.000 POUNDS PER HOUR NOMINAL |
ASND | DRAFT TYPE | FORCED |
AMSE | VOLTAGE RATING | 120.0 VOLTS NOMINAL |
BLSH | MAINTENANCE PARTS | PROVIDED |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | ACDC,AMSE |
ACDC | CURRENT TYPE | DC |
BLSK | PACKAGED BOILER | PROVIDED |
BLHY | FORCED CIRCULATION FEATURE | NOT PROVIDED |
BKXM | DRUM QUANTITY | 2 |
ARNH | OPERATING POSITION | INCLINED |
ASQR | FIRING TYPE | OIL |
BLSL | SUPERHEATER | NOT PROVIDED |
AKYD | ACCESSORY COMPONENTS AND QUANTITY | BLOWER 1,CONTROLLER 1,MOTOR 1,PUMP FEED WATER 1,PUMP FUEL 1 |
BLJC | IGNITION METHOD | MANUAL |
BLHS | OIL BURNER QUANTITY | 1 |
BLSG | MARINE SERVICE DESIGN FEATURE | PROVIDED |
SHPE | SHAPE | BENT |
BLHX | WATERWALLS | PROVIDED |
AWGH | TUBE TYPE | WATER |
BLHQ | MAXIMUM SUPERHEATED STEAM TEMP RATING | NOT RATED |