Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
59915 | SERVICE & SALES INC. |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
STYL | STYLE DESIGNATOR | SHRINKABLE |
ABHP | OVERALL LENGTH | 4.000 FEET NOMINAL |
FLEX | FLEXIBILITY | FLEXIBLE |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 50.0 |
ABJH | TEMP RATING | -67.0 DEG FAHRENHEIT AND 275.0 DEG FAHRENHEIT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AFZM | RECOVERED INSIDE DIAMETER | 0.250 INCHES MAXIMUM |
AFZL | EXPANDED INSIDE DIAMETER | 0.500 INCHES MINIMUM |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 500.0 VOLTS PER MIL /0.001 INCH/ |
MATL | MATERIAL | PLASTIC,MODIFIED POLYOLEFIN,AIRESEARCH MANUFACTURING COMPANY |
AFZN | RECOVERED WALL THICKNESS | 0.022 INCHES MINIMUM AND 0.028 INCHES MAXIMUM |
HUES | COLOR | WHITE |