Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
70210 | HONEYWELL INTERNATIONAL INC. DBA HON |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFZL | EXPANDED INSIDE DIAMETER | 0.375 INCHES MINIMUM |
STYL | STYLE DESIGNATOR | SHRINKABLE |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND CORROSION RESISTANT AND MILDEW RESISTANT |
ABHP | OVERALL LENGTH | 4.000 FEET NOMINAL |
FLEX | FLEXIBILITY | FLEXIBLE |
AFZM | RECOVERED INSIDE DIAMETER | 0.187 INCHES MAXIMUM |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 50.0 |
ABJH | TEMP RATING | -67.0 DEG FAHRENHEIT AND 275.0 DEG FAHRENHEIT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 500.0 VOLTS PER MIL /0.001 INCH/ |
MATL | MATERIAL | PLASTIC,MODIFIED POLYOLEFIN |
AFZN | RECOVERED WALL THICKNESS | 0.022 INCHES MINIMUM AND 0.028 INCHES MAXIMUM |
HUES | COLOR | WHITE |