Part Number
Part Number:
NSN:
NIIN:
Item Name:
SOLENOID , ELECTRICAL
Definition:
AN ITEM CONSISTING OF ONE OR MORE COILS SURROUNDING AN IRON CORE. THE COIL(S) AND THE CORE ARE MOVEABLE IN RELATION TO EACH OTHER. THE AXIAL OR ROTARY MOVEMENT IS A RESULT OF THE MAGNETIC FLUX OF THE COIL. IT IS DESIGNED TO CONVERT ELECTRICAL ENERGY INTO MECHANICAL ENERGY. IT DOES NOT INCLUDE SWITCH CONTACTS. SEE ALSO RELAY, ELECTROMAGNETIC, AND ELECTROMAGNETIC ACTUATOR.
CAGE Information
Code | Company |
---|---|
78388 | WOODWARD CONTROLS INC. |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
AEHZ | MAXIMUM OPERATING TEMP | 73.0 DEG FAHRENHEIT |
APAF | MAGNETIC COIL QUANTITY | 2 |
CNXW | LINEAR FORCE DELIVERED | 16.00 POUNDS |
ABTD | MOUNTING SLOT WIDTH | 0.281 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL |
ABPM | BODY DIAMETER | 2.500 INCHES NOMINAL |
AXNP | CURRENT RATING | 14.000 AMPERES NOMINAL |
ASXH | VOLTAGE RATING IN VOLTS | 24.0 DC MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
ADAQ | BODY LENGTH | 4.990 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.500 INCHES NOMINAL |
CNYD | ENERGIZING STROKE MAXIMUM LENGTH | 1.000 INCHES |
CNXX | POWER TAKEOFF CONNECTION TYPE | EXTERNAL THREADS |
APXH | TERMINAL LOCATION | END OPPOSITE ACTUATOR |
APNP | DUTY TYPE | CONTINUOUS |
FEAT | SPECIAL FEATURES | SLOT LENGTH 0.500 IN |
AFGK | ACTUATOR LENGTH | 1.000 INCHES NOMINAL |
CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
CNXT | ACTUATOR STROKE TYPE | PULL |