Part Number
Definition:
AN ITEM DESIGNED PRIMARILY FOR THE CONDUCTION OF RADIO FREQUENCY ENERGY, AND CONSISTING OF TWO OR MORE CONDUCTORS SUPPORTED IN FIXED SPATIAL RELATIONSHIP(S) ALONG THEIR OWN LENGTH. SINCE THE CHARACTERISTIC IMPEDANCE OF THE LINE IS DETERMINED BY THE SPATIAL RELATIONSHIPS OF THE CONDUCTORS, WHICH ARE SUFFICIENTLY RIGID TO MAINTAIN THESE RELATIONSHIPS BETWEEN SUPPORTS, THE CONFIGURATION OF THE ITEM IS USUALLY NOT SUSCEPTIBLE TO MECHANICAL MANIPULATION; THAT IS, IT IS NOT NORMALLY FLEXIBLE. INCLUDES A SINGLE CONDUCTOR INCLOSED IN AN OUTER CONCENTRIC CONDUCTOR (COAXIAL) OR TWO OR MORE CONDUCTORS LAID PARALLEL. ALL TYPES HAVE LOW LOSS OR SPECIAL CHARACTERISTICS AT HIGH FREQUENCIES. MAY INCLUDE FITTINGS OR TERMINATIONS. FOR ITEMS HAVING CONTINUOUS HOMOGENEOUS DIELECTRIC, SEE CABLE, RADIO FREQUENCY. SEE ALSO LINE SECTION, RADIO FREQUENCY TRANSMISSION.
CAGE Information
Code | Company |
---|---|
0NKU0 | LCT ELECTRONICS |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AJDD | CHARACTERISTIC IMPEDANCE IN OHMS | 50.0 |
AQCE | ACCOMMODATED CONDUCTOR TYPE | COAXIAL |
ACVL | CONDUCTOR SIZE | 1 AWG |
SURF | SURFACE TREATMENT | SILVER PLATED WITH RHODIUM FLASH |
AQRW | CONDUCTOR SURFACE TREATMENT | SILVER PLATED WITH RHODIUM FLASH |
ABHE | OUTSIDE DIAMETER | 1.000 INCHES NOMINAL |
APYQ | CONDUCTOR MATERIAL | BRASS |
AQAZ | INSULATION SPACER MATERIAL | PLASTIC, LOW-LOSS |
AQRX | TUBING OUTSIDE DIAMETER | 1.000 INCHES NOMINAL |
MATL | MATERIAL | BRASS |
AQRY | TUBING INSIDE DIAMETER | 0.810 INCHES NOMINAL |
APZB | OPERATING VOLTAGE RATING | 1000.0 VOLTS |
AJDF | TERMINATION IDENTIFICATION | TYPE UG352A/U |
AQBB | TERMINATION CONTROLLING AGENCY | DOUGLAS MICROWAVE |
APZA | CAPACITANCE IN PICOFARADS PER UNIT LENGTH | 18.8 PER FOOT |
AAJU | OVERALL LENGTH | 9.125 INCHES |
APZC | OUTER CONDUCTOR | INCLUDED |
AQBD | TERMINAL FITTING | NOT INCLUDED |
AMQN | CONDUCTOR QUANTITY | 1 |
AQBA | INSULATION SPACER OUTSIDE DIAMETER | 0.839 INCHES MAXIMUM |