Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
73473 | ARMATRON INTL INC |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABGN | BOARD OVERALL LENGTH | 7.000 INCHES |
ABGN | BOARD OVERALL LENGTH | 7.000 INCHES |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
CBBL | FEATURES PROVIDED | FANNING HOLES |
PRMT | PRECIOUS MATERIAL | SILVER |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD AND PAPER BOARD |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | L-P-513,TYPE PBE FED SPEC SINGLE MATERIAL RESPONSE BOARD |
ABGP | BOARD OVERALL WIDTH | 3.500 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 434 SINGLE |
FEAT | SPECIAL FEATURES | TERMINALS IRREGULARLY SPACED |
AAQL | BODY STYLE | STRIP TYPE |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
CWLG | TERMINAL PATTERN ARRANGEMENT | RANDOM |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINALS SILVER |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 2.875 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.500 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.969 INCHES |
SFTT | SURFACE TREATMENT | SILVER TERMINALS |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 25 SINGLE |
ABGT | BOARD THICKNESS | 0.125 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 1.000 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.154 INCHES |