Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
0C9D4 HARRIS TECHNICAL SERVICES CORP

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SECOND LOCATION
FREQ FREQUENCY IN HERTZ 400.0 THIRD LOCATION
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
AKPX POLE QUANTITY 4
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 10 THREADED STUD
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED MOISTURE RESISTANT AND SALT WATER RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.175 MINIMUM AT 200 PCT FIRST LOCATION AND 2.000 MAXIMUM AT 200 PCT FIRST LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT THIRD LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 70.0 AMPERES AC FIRST LOCATION
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP FIRST LOCATION
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC AND 50.0 DC
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC THIRD LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 70.0 AMPERES AC SECOND LOCATION
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SECOND LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 4 TOGGLE
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.175 MINIMUM AT 200 PCT SECOND LOCATION AND 2.000 MAXIMUM AT 200 PCT SECOND LOCATION
FREQ FREQUENCY IN HERTZ 400.0 FIRST LOCATION
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP THIRD LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERVOLTAGE FOURTH LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SECOND LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, THREE, AND FOUR LINKED
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC AND 2.5 DC
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 70.0 AMPERES AC THIRD LOCATION
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 DC FOURTH LOCATION
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
ADTV CASE MATERIAL PLASTIC
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC FIRST LOCATION
AXHR MOUNTING FACILITY TYPE AND QUANTITY 8 THREADED HOLE
CPRQ RESET METHOD MANUAL
CRTK SWITCH TERMINAL TYPE QUICK DISCONNECT, MALE
THSD THREAD SERIES DESIGNATOR UNC
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY FIRST LOCATION
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
ADAQ BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
ADAT BODY WIDTH 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 FIRST LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 28.0 DC FOURTH LOCATION
CPRW ACTUATOR FUNCTION TRIP-RESET
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.175 MINIMUM AT 200 PCT THIRD LOCATION AND 2.000 MAXIMUM AT 200 PCT THIRD LOCATION
FREQ FREQUENCY IN HERTZ 400.0 SECOND LOCATION
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SECOND LOCATION
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC THIRD LOCATION
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CPSM INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP FOURTH LOCATION
FEAT SPECIAL FEATURES POLE FOUR TRIPS WITH VOLTS ONLY
CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS FOURTH LOCATION
AJEC BOSS HEIGHT 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SECOND LOCATION
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SECOND LOCATION
CMLP THREAD QUANTITY PER INCH 32
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT FIRST LOCATION
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY THIRD LOCATION
CQJX NOMINAL THREAD SIZE 0.138 INCHES
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC FIRST LOCATION
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 THIRD LOCATION

Similar Parts

SCD51990322-001 , SCD51990322001 , 5925-01-226-5942 , 5925012265942 , 012265942