Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
INSULATION SLEEVING , ELECTRICAL

Definition:

A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.

CAGE Information

Code Company
0FW39 BAE SYSTEMS TACTICAL VEHICLE SYSTEMS

Federal Supply Class

Title

ELECTRICAL INSULATORS AND INSULA

Inclusions:

INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AFZL EXPANDED INSIDE DIAMETER 1.000 INCHES MINIMUM
AFZL EXPANDED INSIDE DIAMETER 1.000 INCHES MINIMUM
HUES COLOR BLACK
STYL STYLE DESIGNATOR SHRINKABLE
ABHP OVERALL LENGTH 4.000 FEET NOMINAL
ADZC ENVIRONMENTAL PROTECTION SOLVENT RESISTANT AND CORROSION RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT
AFZN RECOVERED WALL THICKNESS 0.070 INCHES NOMINAL
ABJH TEMP RATING -55.0 DEG CELSIUS AND 110.0 DEG CELSIUS
CQBC MINIMUM TENSILE STRENGTH 2000 POUNDS PER SQUARE INCH
AARG RELIABILITY INDICATOR NOT ESTABLISHED
UKBG DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS 800.0 VOLTS PER MIL /0.001 INCH/
MATL MATERIAL PLASTIC, POLYOLEFIN
AGAU HEAT SHRINKAGE RATING IN PERCENT 60.0
AFZM RECOVERED INSIDE DIAMETER 0.400 INCHES MAXIMUM
FLEX FLEXIBILITY SEMIRIGID

Similar Parts

SCL1INBLACK , SCL1INBLACK , 5970-00-275-1851 , 5970002751851 , 002751851