Part Number
Definition:
A CABINETLIKE ITEM USUALLY WITH A FRONT WORK AREA AND CONSISTING OF THE NECESSARY INSTRUMENTATION, INTEGRAL HYDRAULIC SYSTEM AND COMPONENT MOUNTING FACILITIES. DESIGNED TO PROVIDE THE HYDRAULIC PRESSURE FOR TESTING AND/OR CALIBRATING HYDRAULIC SYSTEM COMPONENTS, SUCH AS VALVES, ACTUATING CYLINDERS, PRESSURE REGULATORS, ACCUMULATORS, HOSE LINES, HAND AND/OR ENGINE DRIVEN PUMPS AND THE LIKE. MAY INCLUDE FACILITIES FOR FILLING AND CHECKING HYDRAULIC SYSTEMS FOR LEAKAGE AND PERFORMANCE. SEE ALSO PUMPING UNIT, HYDRAULIC.
CAGE Information
Code | Company |
---|---|
14170 | HUGHES MISSILE SYSTEMS CO SAN DIEGO |
Federal Supply Class
Title
AIRCRAFT MAINTENANCE AND REPAIR
Inclusions:
INCLUDES MAINTENANCE STANDS DESIGNED FOR SUPPORT OF AIRCRAFT ASSEMBLIES DURING REPAIR OR OVERHAUL; TEST STANDS AND TEST EQUIPMENT SPECIALLY DESIGNED FOR MAINTENANCE AND REPAIR OF AIRCRAFT COMPONENTS SUCH AS: ENGINES, GENERATORS, HYDRAULIC SYSTEMS, ARMAMENT, AUTOMATIC PILOT, FIRE CONTROL, FLIGHT CONTROL, AND NAVIGATIONAL SYSTEMS.
Exclusions:
EXCLUDES HAND TOOLS; AIRFIELD MAINTENANCE PLATFORMS; BASIC TYPES OF ELECTRICAL AND ELECTRONIC TEST INSTRUMENTS, INCLUDING THOSE SPECIALLY DESIGNED, SUCH AS AMMETERS, VOLTMETERS OHMMETERS, MULTIMETERS, AND SIMILAR INSTRUMENTS, AS SHOWN IN THE INDEXES TO THE FSC; TEST APPARATUS USED FOR BOTH COMMUNICATIONS AND OTHER ELECTRICAL AND ELECTRONIC EQUIPMENT.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AYJM | ACCUMULATOR | NOT INCLUDED |
AYJM | ACCUMULATOR | NOT INCLUDED |
AAYJ | HYDRAULIC FLUID FLOW RATE | 30.0 GALLONS PER MINUTE |
AAYJ | HYDRAULIC FLUID FLOW RATE | 15.0 GALLONS PER MINUTE |
ALBY | USAGE DESIGN | AIRCRAFT HYDRAULIC SYSTEM OR INDIVIDUAL HYDRAULIC UNITS |
BGST | PRESSURE RATING | 3000.0 POUNDS PER SQUARE INCH NOMINAL AND 5000.0 POUNDS PER SQUARE INCH NOMINAL |
CGYM | PRESSURE MANIFOLD SUBCIRCUIT | NOT INCLUDED |
CGYK | ENGINE DRIVEN HYDRAULIC PUMP TESTING DESIGN FEATURE | NOT INCLUDED |
ATJK | POWER SOURCE | GASOLINE ENGINE |
AMQY | INSTALLATION DESIGN | PORTABLE |
CHGR | PRESSURE/SUCTION HOSE | INCLUDED |
CHGQ | FILTERING SYSTEM | INCLUDED |
ZZZT | NONDEFINITIVE SPEC/STD DATA | MJ2A TYPE |
AKYN | FURNISHED ITEMS AND QUANTITY | TACHOMETER,ELECTRIC 1 |
ANCY | HORSEPOWER RATING | 175.0 |
SUPP | SUPPLEMENTARY FEATURES | WELDED STEEL; HAND BRAKES REAR WHEELS; TRAILER MOUNTED MOBILE TESTING UNIT FOR AIRCRAFT HYDRAULIC SYSTEMS; PNEUMATIC PRESSURE: 3 CFM AT 150 PSI; HYDRAULIC PRESSURE: 2700 +/- 50 GMP WHEN DEL 30 GMP W/ZERO FLOW PRESSURE SETTING AT 3000 PSIG |