Part Number
Part Number:
NSN:
NIIN:
Item Name:
TERMINAL , STUD
Definition:
A TERMINAL, GENERALLY POSTLIKE, HAVING AN AXIAL PORTION OF ITS BODY DESIGNED FOR PROJECTING THROUGH OR INTO A PANEL, OR THE LIKE, FOR MOUNTING. REQUIRES THE USE OF TOOL(S) FOR ATTACHMENT OF WIRE. THE CONDUCTOR CONNECTION MAY BE INSULATED FROM THE MOUNTING. EXCLUDES TERMINAL, FEEDTHRU. SEE ALSO TERMINAL, QUICK DISCONNECT AND TERMINAL SET, QUICK DISCONNECT.
CAGE Information
Code | Company |
---|---|
11375 | ACCURATE ELECTRONICS INC |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABET | THREAD LENGTH | 0.078 INCHES |
MATT | MATERIAL | COPPER ALLOY OVERALL EXCEPT INSULATION |
AAMP | MOUNTING THREAD DIAMETER | 0.086 INCHES |
AALA | LARGEST DIAMETER | 0.072 INCHES SINGLE END |
AAEY | TERMINAL LENGTH | 0.136 INCHES |
AGTA | BASIC SHAPE STYLE | NONTUBULAR, HEX |
AAJT | OVERALL HEIGHT | 0.390 INCHES |
ATGD | MOUNTING THREAD SERIES | UNC |
AAGW | WIDTH ACROSS FLATS | 0.156 INCHES |
AALD | TURRET MINOR DIAMETER | 0.047 INCHES SINGLE END |
AALV | ELECTRICAL INSULATION FEATURE | STANDOFF INSULATION |
AALX | MOUNTING METHOD STYLE | TAPPED HOLE |
MATT | MATERIAL | PLASTIC DIALLYL PHTHALATE INSULATION |
AAPA | DRY FLASHOVER VOLTAGE RATING IN VOLTS | 3000.0 |
AAPC | IDENTIFICATION CODE COLOR | GREEN |
CSFJ | CONDUCTOR ACCOMMODATION TYPE | DOUBLE TURRET SINGLE END |
SFTT | SURFACE TREATMENT | TIN OVERALL EXCEPT INSULATION SINGLE LAYER |