Part Number
Part Number:
NSN:
NIIN:
Item Name:
BACKSHELL , ELECTRICAL CONNECTOR
Definition:
AN ITEM SPECIFICALLY DESIGNED TO BE PLACED AROUND THAT PORTION OF A CONNECTOR, RECEPTABLE, ELECTRICAL OR CONNECTOR, PLUG, ELECTRICAL WHICH CONTAINS THE FACILITIES FOR ATTACHING WIRES OR CABLES. IT MAY BE DESIGNED TO PROVIDE THE NECESSARY ACCOMODATIONS BETWEEN AN ELECTRICAL CABLE CLAMPING DEVICE AND AN ELECTRICAL CONNECTOR SHELL, OR IT MAY INCLUDE THE CLAMPING DEVICE. IT MAY BE USED FOR SHIELDING AGAINST ELECTRICAL INTERFERENCE, MECHANICAL INJURY, OR PHYSICAL DAMAGE DUE TO ENVIRONMENTAL CONDITIONS.
CAGE Information
Code | Company |
---|---|
07418 | JOSLYN SUNBANK COMPANY LLC |
Federal Supply Class
Title
CONNECTORS, ELECTRICAL
Inclusions:
INCLUDES PLUGS; JACKS; RECEPTACLES, ELECTRONIC COMPONENT SOCKETS AND ASSOCIATED ACCESSORIES
Exclusions:
EXCLUDES INTERCONNECTORS, FIBER OPTIC
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED COUPLING |
STYL | STYLE DESIGNATOR | ANGLE TYPE W/CLAMP |
AGTW | CABLE OPENING DIAMETER | 0.700 INCHES MINIMUM AND 0.938 INCHES MAXIMUM |
ALJP | SIZE DESIGNATION | 22 |
ABMK | OVERALL WIDTH | 1.907 INCHES MINIMUM AND 1.969 INCHES MAXIMUM |
AKFA | DISTANCE FROM CENTERLINE TO CABLE END | ANY ACCEPTABLE |
THSD | THREAD SERIES DESIGNATOR | UNEF |
AKEZ | DISTANCE FROM CENTERLINE TO CONNECTOR END | ANY ACCEPTABLE |
CMLP | THREAD QUANTITY PER INCH | 18 |
MATL | MATERIAL | ALUMINUM ALLOY |
AAJF | THREAD DIRECTION | RIGHT-HAND |
ADMW | BODY ANGLE IN DEG | 90.0 |
CQJX | NOMINAL THREAD SIZE | 1.312 INCHES |
SURF | SURFACE TREATMENT | CADMIUM |
ABAH | SEAL MATERIAL | RUBBER OR RUBBER, SILICONE BASE |
AKRF | SEAL TYPE | PREFORMED PACKING |
AKRD | CABLE OPENING QUANTITY | 1 |
AAJD | THREAD CLASS | 2B |