Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
06090 | TYCO ELECTRONICS CORPORATION DIV RAY |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFZN | RECOVERED WALL THICKNESS | 0.065 INCHES NOMINAL |
HUES | COLOR | BLACK |
STYL | STYLE DESIGNATOR | SHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 600 POUNDS PER SQUARE INCH |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AFZL | EXPANDED INSIDE DIAMETER | 0.870 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 500.0 |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND CHEMICAL RESISTANT AND MILDEW RESISTANT AND FLAME RESISTANT AND SOLVENT RESISTANT |
MATL | MATERIAL | SILICONE RUBBER |
AFZM | RECOVERED INSIDE DIAMETER | 0.500 INCHES NOMINAL |