Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | BLACK |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |
FLEX | FLEXIBILITY | FLEXIBLE |
ABJH | TEMP RATING | -10.0 DEG CELSIUS AND 105.0 DEG CELSIUS |
MATL | MATERIAL | PLASTIC,POLYVINYL CHLORIDE,MIL-I-631,TYPE F,FORM U,SUBFORM UA,GRADE C,CLASS 1,CATEGORY 1 |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AAGT | WALL THICKNESS | 0.013 INCHES MINIMUM AND 0.019 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 800.0 VOLTS PER MIL /0.001 INCH/ |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND MILDEW RESISTANT AND OIL RESISTANT |
AARX | INSIDE DIAMETER | 0.057 INCHES MINIMUM AND 0.067 INCHES MAXIMUM |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |
ZZZT | NONDEFINITIVE SPEC/STD DATA | UA SUBFORM AND 15 AWG SIZE AND C GRADE AND U FORM AND 1 CATEGORY AND 1 CLASS AND F TYPE |