Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
80063 US ARMY COMMUNICATIONS & ELECTRONICS

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 19.80 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 19.80 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
ADAU BODY HEIGHT 4.000 INCHES MAXIMUM
AKNA INCLOSURE TYPE FULLY INCLOSED
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 6.000 POUNDS
CRMJ WINDING POWER RATING 2.8 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
ACZF MAXIMUM TRANSFORMER POWER RATING 291.9 VOLT-AMPERE SINGLE COMPONENT
ABTB MOUNTING HOLE DIAMETER 0.187 INCHES NOMINAL SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 10.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRBZ WINDING OPERATING CURRENT 1.84 AMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ADAQ BODY LENGTH 4.750 INCHES MAXIMUM
FEAT SPECIAL FEATURES ONE PRIMARY WINDING; TWELVE SECONDARY WINDINGS
CRMJ WINDING POWER RATING 31.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 10.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 39 TAB, SOLDER LUG
CRBZ WINDING OPERATING CURRENT 204.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY
AXGY MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
CRMJ WINDING POWER RATING 3.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 12 SECONDARY SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 173.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 4TH SECONDARY
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZD TRANSFORMER WINDING CONNECTION TYPE DELTA-DELTA
CWJS WINDING OPERATING VOLTAGE 196.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CRBZ WINDING OPERATING CURRENT 81.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY
CRMJ WINDING POWER RATING 7.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
ADAT BODY WIDTH 2.500 INCHES MAXIMUM
AEHZ MAXIMUM OPERATING TEMP 155.0 DEG CELSIUS