TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
80063 US ARMY COMMUNICATIONS & ELECTRONICS

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ACZB FREQUENCY RATING 15.0 KILOHERTZ MINIMUM SINGLE COMPONENT AND 25.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 10.61 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CRBZ WINDING OPERATING CURRENT 424.2 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
ADAR BODY OUTSIDE DIAMETER 1.005 INCHES MAXIMUM
AKNA INCLOSURE TYPE FULLY INCLOSED
CWJS WINDING OPERATING VOLTAGE 2.12 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CWJS WINDING OPERATING VOLTAGE 424.00 AC MAJOR WET SINGLE COMPONENT 3RD SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 8 PIN
CWJS WINDING OPERATING VOLTAGE 8.49 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 12.73 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY
CBBL FEATURES PROVIDED COLOR CODED TERMINAL
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ADAQ BODY LENGTH 0.505 INCHES MAXIMUM
AXGY MOUNTING METHOD TERMINAL SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 84.8 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
CRBZ WINDING OPERATING CURRENT 2.1 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY
AEHZ MAXIMUM OPERATING TEMP 155.0 DEG CELSIUS