Part Number
Part Number:
NSN:
NIIN:
Item Name:
WAVEGUIDE ASSEMBLY
Definition:
AN ITEM CONSISTING OF ONE OR MORE DEFINITE LENGTHS OF STRAIGHT OR FORMED, FLEXIBLE OR RIGID, PREFABRICATED HOLLOW TUBING OF CONDUCTIVE MATERIAL. THE TUBING HAS A PREDETERMINED CROSS SECTION AND IS DESIGNED TO GUIDE OR CONDUCT HIGH FREQUENCY ELECTROMAGNETIC ENERGY THROUGH ITS INTERIOR. ONE OR MORE ENDS ARE TERMINATED. MAY INCLUDE COMMON MOUNTING OF A SWITCH, WAVE GUIDE, A DUMMY LOAD, ELECTRICAL AND OTHER COMPONENTS SUCH AS WAVEGUIDE SECTION, CABLE TERMINAL CHAMBER AND THE LIKE. EXCLUDES COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; AND TUNER, WAVEGUIDE.
CAGE Information
Code | Company |
---|---|
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
MATT | MATERIAL | COPPER ALLOY FOURTH TUBING SEGMENT AND FLANGE |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.746 INCHES MINIMUM AND 0.754 INCHES MAXIMUM |
AHTD | FLANGE DEPTH | 0.610 INCHES MINIMUM SECOND FLANGE AND 0.610 INCHES MAXIMUM SECOND FLANGE |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND FLANGE ALL CONNECTION FACILITIES |
AHSF | FLANGE QUANTITY | 2 |
SFTT | SURFACE TREATMENT | PAINT ALL TUBING SEGMENT OUTSIDE SURFACES |
AAJD | THREAD CLASS | 2B SECOND FLANGE ALL CONNECTION FACILITIES |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.368 INCHES MINIMUM AND 1.376 INCHES MAXIMUM |
AHSY | FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM SECOND FLANGE AND 0.501 INCHES MAXIMUM SECOND FLANGE |
AHRW | TUBING TWIST TYPE | STRAIGHT TWIST THIRD TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY THIRD TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIRST TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIRST TUBING SEGMENT |
AHTA | FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
AHSX | FLANGE INSIDE WIDTH | 1.118 INCHES MINIMUM SECOND FLANGE AND 1.126 INCHES MAXIMUM SECOND FLANGE |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.618 INCHES MINIMUM AND 0.626 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
AHRX | TUBING TWIST ANGLE IN DEG | 90.0 THIRD TUBING SEGMENT |
CQGM | MAXIMUM OPERATING PRESSURE | 15.0 POUNDS PER SQUARE INCH GAGE |
FLEX | FLEXIBILITY | FLEXIBLE FOURTH TUBING SEGMENT |
AHSX | FLANGE INSIDE WIDTH | 1.118 INCHES MINIMUM FIRST FLANGE AND 1.126 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.496 INCHES MINIMUM AND 1.504 INCHES MAXIMUM |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS THIRD TUBING SEGMENT |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
MATT | MATERIAL | COPPER ALLOY SECOND TUBING SEGMENT |
AHTX | INSERTION LOSS IN DECIBELS | 0.10 |
FLEX | FLEXIBILITY | FLEXIBLE SECOND TUBING SEGMENT |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND FLANGE ALL CONNECTION FACILITIES |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AHTD | FLANGE DEPTH | 0.610 INCHES MINIMUM FIRST FLANGE AND 0.640 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM FIRST FLANGE AND 0.501 INCHES MAXIMUM FIRST FLANGE |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
FLEX | FLEXIBILITY | RIGID THIRD TUBING SEGMENT |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
MATT | MATERIAL | ALUMINUM ALLOY FIRST TUBING SEGMENT AND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED FOURTH TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED SECOND TUBING SEGMENT |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
AHTA | FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |