WAVEGUIDE ASSEMBLY

Definition:

AN ITEM CONSISTING OF ONE OR MORE DEFINITE LENGTHS OF STRAIGHT OR FORMED, FLEXIBLE OR RIGID, PREFABRICATED HOLLOW TUBING OF CONDUCTIVE MATERIAL. THE TUBING HAS A PREDETERMINED CROSS SECTION AND IS DESIGNED TO GUIDE OR CONDUCT HIGH FREQUENCY ELECTROMAGNETIC ENERGY THROUGH ITS INTERIOR. ONE OR MORE ENDS ARE TERMINATED. MAY INCLUDE COMMON MOUNTING OF A SWITCH, WAVE GUIDE, A DUMMY LOAD, ELECTRICAL AND OTHER COMPONENTS SUCH AS WAVEGUIDE SECTION, CABLE TERMINAL CHAMBER AND THE LIKE. EXCLUDES COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; AND TUNER, WAVEGUIDE.

CAGE Information

Code Company
54647 MICROTECH INC.

Federal Supply Class

Title

ANTENNAS, WAVEGUIDES, AND RELATE

Inclusions:

INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.

Exclusions:

EXCLUDES TOWER STRUCTURES.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AAJD THREAD CLASS 2B FIRST FLANGE ALL CONNECTION FACILITIES
CTCJ FLANGE STYLE CHOKE TYPE FIRST FLANGE
CSQT FLANGE CONNECTING FACILITY AND QUANTITY 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
AHTA FLANGE OUTSIDE HEIGHT 1.890 INCHES MAXIMUM SECOND FLANGE
PRMT PRECIOUS MATERIAL SILVER
AHSZ FLANGE OUTSIDE WIDTH 1.890 INCHES MAXIMUM SECOND FLANGE
THSD THREAD SERIES DESIGNATOR UNC FIRST FLANGE ALL CONNECTION FACILITIES
AHTX INSERTION LOSS IN DECIBELS 0.04
AHSF FLANGE QUANTITY 2
CSRM WAVEGUIDE FIRST LEG LENGTH 5.250 INCHES NOMINAL
AHTA FLANGE OUTSIDE HEIGHT 1.860 INCHES MINIMUM SECOND FLANGE AND 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE
AAJF THREAD DIRECTION RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
AHRV TUBING WALL CONSTRUCTION STYLE SEAMLESS FIRST TUBING SEGMENT
SFTT SURFACE TREATMENT SILVER SECOND TUBING SEGMENT INSIDE SURFACES
AHSY FLANGE INSIDE HEIGHT 0.501 INCHES MAXIMUM FIRST FLANGE
FLEX FLEXIBILITY RIGID FIRST TUBING SEGMENT
AHSZ FLANGE OUTSIDE WIDTH 1.860 INCHES MINIMUM SECOND FLANGE AND 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE
CSQT FLANGE CONNECTING FACILITY AND QUANTITY 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
STYL STYLE DESIGNATOR FOUR BEND TYPE
CSFC WAVEGUIDE OUTSIDE HEIGHT 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM
CQGM MAXIMUM OPERATING PRESSURE 15.0 POUNDS PER SQUARE INCH GAGE
AHTD FLANGE DEPTH 0.423 INCHES MINIMUM SECOND FLANGE AND 0.610 INCHES MINIMUM FIRST FLANGE AND 0.640 INCHES MAXIMUM FIRST FLANGE
CQJX NOMINAL THREAD SIZE 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
AHTB FLANGE INSIDE DIAMETER 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE
CTFP WAVEGUIDE SECOND LEG LENGTH 2.970 INCHES NOMINAL
CTCJ FLANGE STYLE COVER TYPE SECOND FLANGE
AHTD FLANGE DEPTH 0.453 INCHES MAXIMUM SECOND FLANGE
MATT MATERIAL COPPER ALLOY SECOND TUBING SEGMENT
AHSY FLANGE INSIDE HEIGHT 0.628 INCHES MINIMUM SECOND FLANGE AND 0.493 INCHES MINIMUM FIRST FLANGE AND 0.631 INCHES MAXIMUM SECOND FLANGE
PMLC PRECIOUS MATERIAL AND LOCATION INSIDE FLEXIBLE TUBING SEGMENT SURFACES SILVER
FLEX FLEXIBILITY FLEXIBLE SECOND TUBING SEGMENT
AAGR CROSS-SECTIONAL SHAPE STYLE INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
MATT MATERIAL ALUMINUM ALLOY ALL FLANGE
AHTW VOLTAGE STANDING WAVE RATIO 1.10
MATT MATERIAL ALUMINUM ALLOY FIRST TUBING SEGMENT
AHSX FLANGE INSIDE WIDTH 1.126 INCHES MAXIMUM FIRST FLANGE
AHTN FLANGE CONNECTING HOLE DIAMETER 0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES
CRFH WAVEGUIDE INSIDE WIDTH 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM
CQHN WAVEGUIDE OUTSIDE WIDTH 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM
CXBG WAVEGUIDE FOURTH LEG LENGTH 6.700 INCHES NOMINAL
AHSX FLANGE INSIDE WIDTH 1.118 INCHES MINIMUM FIRST FLANGE AND 1.253 INCHES MINIMUM SECOND FLANGE AND 1.256 INCHES MAXIMUM SECOND FLANGE
CSRN WAVEGUIDE FIFTH LEG LENGTH 2.800 INCHES NOMINAL
CWBP WAVEGUIDE THIRD LEG LENGTH 7.190 INCHES NOMINAL
AHRV TUBING WALL CONSTRUCTION STYLE CORRUGATED SECOND TUBING SEGMENT
ZZZV FSC APPLICATION DATA ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
CRLB WAVEGUIDE INSIDE HEIGHT 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM