CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC AND 50.0 DC |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC AND 50.0 DC |
FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
10.0 AMPERES AC ALL LOCATIONS |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
1.0 AC AND 0.5 DC |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
15.000 MAXIMUM AT 150 PCT ALL LOCATIONS AND 0.020 MINIMUM AT 400 PCT ALL LOCATIONS AND 3.000 MINIMUM AT 150 PCT ALL LOCATIONS AND 0.100 MAXIMUM AT 400 PCT ALL LOCATIONS |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
6.000 MINIMUM ALL LOCATIONS AND 30.000 MAXIMUM ALL LOCATIONS |
AKPX |
POLE QUANTITY |
2 |
THSD |
THREAD SERIES DESIGNATOR |
UNEF |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
300.0 AC ALL LOCATIONS |
CPRX |
ACTUATOR POSITION DESIGNATION |
BETWEEN POLE ONE AND TWO |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.780 INCHES MAXIMUM |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 CONTROL |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
CPRQ |
RESET METHOD |
MANUAL |
ABXD |
BUSHING LENGTH |
0.375 INCHES MAXIMUM |
TTQY |
TERMINAL TYPE AND QUANTITY |
4 WIRE HOOK |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.875 INCHES NOMINAL |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
CRTK |
SWITCH TERMINAL TYPE |
TAB, SOLDER LUG |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
HERMETICALLY SEALED |
ADAQ |
BODY LENGTH |
1.500 INCHES MAXIMUM |
ADTV |
CASE MATERIAL |
METAL |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.625 INCHES NOMINAL |
ADAT |
BODY WIDTH |
1.250 INCHES MAXIMUM |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC ALL LOCATIONS |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING W/PANEL SEAL |
AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
CMLP |
THREAD QUANTITY PER INCH |
32 |