Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAQ | BODY LENGTH | 3.062 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
ADAT | BODY WIDTH | 3.562 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 13.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
ADAU | BODY HEIGHT | 3.844 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |