Part Number
Part Number:
NSN:
NIIN:
Item Name:
TERMINAL , LUG
Definition:
A TERMINAL DESIGNED TO BE AFFIXED, USUALLY AT ONE END, TO A POST, STUD, CHASSIS, OR THE LIKE FOR MOUNTING. IT HAS PROVISIONS FOR ATTACHMENT OF WIRE(S) OR SIMILAR ELECTRICAL CONDUCTOR(S) IN ORDER TO ESTABLISH AN ELECTRICAL CONNECTION AND COULD REQUIRE THE USE OF TOOL(S) FOR ATTACHMENT OF WIRE. FOR POST LIKE TERMINALS, SEE TERMINAL STUD. EXCLUDES CLIP, ELECTRICAL; TERMINAL, QUICK DISCONNECT AND TERMINAL FEEDTHRU.
CAGE Information
Code | Company |
---|---|
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAJX | MATERIAL THICKNESS | 0.020 INCHES |
AALB | LARGEST WIDTH | 0.188 INCHES SINGLE END |
AAJV | OVERALL WIDTH | 0.313 INCHES |
CSFJ | CONDUCTOR ACCOMMODATION TYPE | SLANT LUG W/ONE HOLE SINGLE END |
AALV | ELECTRICAL INSULATION FEATURE | UNINSULATED |
AALX | MOUNTING METHOD STYLE | RING |
AGTA | BASIC SHAPE STYLE | SOLDER |
AAKV | MAXIMUM CONDUCTOR SIZE ACCOMMODATED | 20 AWG |
AAMA | MOUNTING HOLE DIAMETER | 0.127 INCHES |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-T-10727,TYPE II MIL SPEC SINGLE TREATMENT RESPONSE OVERALL SINGLE LAYER |
SFTT | SURFACE TREATMENT | TIN OVERALL SINGLE LAYER |
MATT | MATERIAL | COPPER OVERALL |
AAJU | OVERALL LENGTH | 0.625 INCHES |
AAMK | MOUNTING FACILITY THICKNESS | 0.020 INCHES |
AAMC | MOUNTING TONGUE WIDTH | 0.313 INCHES |