Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
80063 US ARMY COMMUNICATIONS & ELECTRONICS

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
AKDX WINDING QUANTITY 1
ABHP OVERALL LENGTH 1.180 INCHES NOMINAL
APCN COIL QUANTITY 1
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 SLOTTED HOLE SINGLE MOUNTING FACILITY
ADZC ENVIRONMENTAL PROTECTION HERMETIC
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
APNA WINDING DC RESISTANCE RATING 600.0 OHMS NOMINAL SINGLE WINDING
APNP DUTY TYPE CONTINUOUS
ABMK OVERALL WIDTH 1.070 INCHES NOMINAL
ABKW OVERALL HEIGHT 0.420 INCHES NOMINAL
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 100.0 MILLIAMPERES DC RESISTIVE LOAD
ABTD MOUNTING SLOT WIDTH 0.096 INCHES NOMINAL SINGLE MOUNTING FACILITY

Similar Parts