Part Number
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
L0563 | CANREP INC |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABJH | TEMP RATING | 200.0 DEG CELSIUS |
HUES | COLOR | WHITE 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
MATT | MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE 2ND POSITION SECONDARY INSULATION ALL CONDUCTORS |
HUES | COLOR | YELLOW 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
HUES | COLOR | BLUE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 5 SINGLES |
HUES | COLOR | GREEN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 29 ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM PEAK OPERATING VOLTAGE ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | NICKEL CORE CONDUCTOR ALL CONDUCTORS |
AGAV | END ITEM IDENTIFICATION | F15 A/B/C/D/E |
AAGR | CROSS-SECTIONAL SHAPE STYLE | FLAT |
HUES | COLOR | RED 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
CXDC | ROUND CONDUCTOR SIZE | 16.000 AWG ALL CONDUCTORS |
AMQN | CONDUCTOR QUANTITY | 4 |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYIMIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
FEAT | SPECIAL FEATURES | CONFORMS TO M22759/92 |