CABLE , SPECIAL PURPOSE , ELECTRICAL
Definition:
TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING OR SHIELD; EACH HAVING CHARACTERISTICS NOT COMPLETELY CONFORMING TO CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY OR CORD, ELECTRICAL. INCLUDES ITEMS HAVING THE COMBINED CHARACTERISTICS OF TWO OR MORE OF THE AFOREMENTIONED NAMES. REFERS TO BULK QUANTITIES ONLY; FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
L0563 | CANREP INC |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
MATT | MATERIAL | COPPER 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
AMQN | CONDUCTOR QUANTITY | 5 |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-W-22759 MIL SPEC ALL MATERIAL RESPONSES 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
CXDC | ROUND CONDUCTOR SIZE | 22 AWG ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-W-22759 MIL SPEC ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | COPPER ALLOY CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | PLASTIC POLYIMIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | NICKEL CORE CONDUCTOR ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | SILVER 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-W-22759 MIL SPEC ALL MATERIAL RESPONSES 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 34 ALL CONDUCTORS |