Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
04322 | SOLARTRON ELECTRONICS INC SUB OF SCH |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SINGLE MOUNTING FACILITY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
ABKW | OVERALL HEIGHT | 1.875 INCHES NOMINAL |
APCN | COIL QUANTITY | 1 |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |
AAJD | THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
APNP | DUTY TYPE | CONTINUOUS |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
ABMK | OVERALL WIDTH | 2.187 INCHES NOMINAL |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 2.250 INCHES NOMINAL |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 40.0 MILLIAMPERES AC SINGLE WINDING |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |