Part Number
Part Number:
NSN:
NIIN:
Item Name:
SOLENOID , ELECTRICAL
Definition:
AN ITEM CONSISTING OF ONE OR MORE COILS SURROUNDING AN IRON CORE. THE COIL(S) AND THE CORE ARE MOVEABLE IN RELATION TO EACH OTHER. THE AXIAL OR ROTARY MOVEMENT IS A RESULT OF THE MAGNETIC FLUX OF THE COIL. IT IS DESIGNED TO CONVERT ELECTRICAL ENERGY INTO MECHANICAL ENERGY. IT DOES NOT INCLUDE SWITCH CONTACTS. SEE ALSO RELAY, ELECTROMAGNETIC, AND ELECTROMAGNETIC ACTUATOR.
CAGE Information
Code | Company |
---|---|
21441 | MOOG AIRCRAFT GROUP DBA S R ENGINEER |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CNXT | ACTUATOR STROKE TYPE | PUSH |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
AXNP | CURRENT RATING | 210.0 MILLIAMPERES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AEXW | MOUNTING BASE WIDTH | 1.320 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
ABPM | BODY DIAMETER | 0.780 INCHES MAXIMUM |
APAF | MAGNETIC COIL QUANTITY | 1 |
ADAQ | BODY LENGTH | 2.010 INCHES MAXIMUM |
APXH | TERMINAL LOCATION | CIRCUMFERENCE |
ADTY | CASE SURFACE TREATMENT | NICKEL |
THSD | THREAD SERIES DESIGNATOR | UNC POWER TAKEOFF FACILITY STUD |
AFGK | ACTUATOR LENGTH | 0.625 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES POWER TAKEOFF FACILITY STUD |
CMLP | THREAD QUANTITY PER INCH | 40 POWER TAKEOFF FACILITY STUD |
AFUR | ACTUATOR DIAMETER | 0.112 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.101 INCHES NOMINAL |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 0.531 INCHES NOMINAL |
CNXX | POWER TAKEOFF CONNECTION TYPE | EXTERNAL THREADS |
AJSS | FREQUENCY IN HERTZ | 400.0 NOMINAL |
AAJD | THREAD CLASS | 2A POWER TAKEOFF FACILITY STUD |
CNXW | LINEAR FORCE DELIVERED | 4.00 OUNCES |
APNP | DUTY TYPE | CONTINUOUS |
AAQL | BODY STYLE | CYLINDRICAL FRAME |
CNYD | ENERGIZING STROKE MAXIMUM LENGTH | 0.150 INCHES |
ASXH | VOLTAGE RATING IN VOLTS | 115.0 AC NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE |
ADTV | CASE MATERIAL | METAL |
AEHZ | MAXIMUM OPERATING TEMP | 90.0 DEG CELSIUS |
ADZC | ENVIRONMENTAL PROTECTION | ANY ACCEPTABLE |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES NOMINAL |