Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
21066 | WAYNE KERR ELECTRONICS INC |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN ALL FUNCTIONS |
AKDX | WINDING QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 56.0 OHMS NOMINAL SINGLE WINDING |
PRMT | PRECIOUS MATERIAL | GOLD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.3 AMPERES DC INDUCTIVE LOAD AND 0.2 AMPERES AC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 110.0 AC AND 24.0 DC |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS GOLD |
APCN | COIL QUANTITY | 1 |
AGAV | END ITEM IDENTIFICATION | NSN 6625-01-458-5920; METER MODULATION; ELECTRIC TEST EQUIPMENT; GPETE |
ABMK | OVERALL WIDTH | 0.413 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
ABKW | OVERALL HEIGHT | 0.453 INCHES MAXIMUM |
APNP | DUTY TYPE | CONTINUOUS |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ABHP | OVERALL LENGTH | 0.610 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 5.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD AND 0.5 AMPERES AC RESISTIVE LOAD |